Appliances tested:
IMEX-SC06, SVC07, SVC05
(5BAR 0,5MPa overall power 3000w)
COMMENTS ON THE RESULTS OF SWAB ANALYSIS CARRIED OUT BY "GIALLOBLU
STUDIO E CONTROLLO PRODOTTI E PRODUZIONI"
Laboratory recognized by the Italian Ministry of Health
Treatments on STAINLESS STEEL were found to be fully effective on all
strains.
Treatments on GRES were found to be fully effective on
Saccaromyces,
E.Coli, Staphylococcus and Streptococcus, while low counts
of
Pseudomonas and
B. cereus
remained on the surfaces.
Treatments on TEFLON were found to be fully effective on all strains,
excpet
B. cereus.
The right side images shows the copy of the test result and below is
the translation into English
Type
of document:
Microbiological test - steam and vacuum appliances with 0,4 MPa
pressure and 3000 Watts power
Date 18.04.2001
Page 1 of 1
Type of surface materail: GRES
Surface contaminated with:
BEFORE the steam vacuum
cleaning treatment (N° of germ colonies
per square centimeter)
AFTER the steam and
vacuum cleaning treatment (N° of germ
colonies per square centimeter)
Saccaromyces
Cerevisiae
98
Pseudomonas
Aeruginosa
112
E.Coli
115
-
Bacillus
Cereus
70
1
Staphilococcus
Aureus
68
-
Steptococcus
Faecalis
77
-
Type
of surface
material: STAINLESS
STEEL INOX
Surface contaminated with:
BEFORE the steam vacuum
cleaning treatment (N° of germ colonies
per square centimeter)
AFTER the steam and
vacuum cleaning treatment (N° of germ
colonies per square centimeter)
Saccaromyces
Cerevisiae
92
Pseudomonas
Aeruginosa
105
E.Coli
138
-
Bacillus
Cereus
95
-
Staphilococcus
Aureus
100
-
Steptococcus
Faecalis
97
-
Type
of surface
material: TEFLON
Surface contaminated with:
BEFORE the steam vacuum
cleaning treatment (N° of germ colonies
per square centimeter)
AFTER the steam and
vacuum cleaning treatment (N° of germ
colonies per square centimeter)
Saccaromyces
Cerevisiae
129
Pseudomonas
Aeruginosa
125
E.Coli
103
-
Bacillus
Cereus
112
2
Staphilococcus
Aureus
100
-
Steptococcus
Faecalis
125
-