Appliances tested:
IMEX-SVC01, SVC02, SVC06
(4BAR 0,4MPa overall power 3000w)
COMMENTS ON THE RESULTS OF SWAB ANALYSIS CARRIED OUT BY "GIALLOBLU
STUDIO E CONTROLLO PRODOTTI E PRODUZIONI"
Laboratory recognized by the Italian Ministry of Health
Treatments on GRES were found to be fully effective on all test
strains.
Treatments on STAINLESS STEEL were found to be fully effective on all
strains except Saccaromyces and B. cereus.
Treatments on TEFLON were found to be fully effective on Pseudomonas
and E.Coli only.
The right side images shows the copy of the test result and below is
the translation into English
Type
of document:
Microbiological test - steam and vacuum appliances with 0,4 MPa
pressure and 3000 Watts power
Date 18.04.2001
Page 1 of 1
Type of surface materail: GRES
Surface contaminated with:
BEFORE the steam vacuum
cleaning treatment (N° of germ colonies
per square centimeter)
AFTER the steam and
vacuum cleaning treatment (N° of germ
colonies per square centimeter)
Saccaromyces
Cerevisiae
105
Pseudomonas
Aeruginosa
133
E.Coli
100
-
Bacillus
Cereus
83
-
Staphilococcus
Aureus
72
-
Steptococcus
Faecalis
100
-
Type
of surface
material: STAINLESS
STEEL INOX
Surface contaminated with:
BEFORE the steam vacuum
cleaning treatment (N° of germ colonies
per square centimeter)
AFTER the steam and
vacuum cleaning treatment (N° of germ
colonies per square centimeter)
Saccaromyces
Cerevisiae
86
Pseudomonas
Aeruginosa
180
E.Coli
106
-
Bacillus
Cereus
96
2
Staphilococcus
Aureus
100
-
Steptococcus
Faecalis
103
-
Type
of surface
material: TEFLON
Surface contaminated with:
BEFORE the steam vacuum
cleaning treatment (N° of germ colonies
per square centimeter)
AFTER the steam and
vacuum cleaning treatment (N° of germ
colonies per square centimeter)
Saccaromyces
Cerevisiae
105
Pseudomonas
Aeruginosa
128
E.Coli
110
-
Bacillus
Cereus
110
3
Staphilococcus
Aureus
96
2
Steptococcus
Faecalis
130
1